Engineering Solutions with the Dual Action Rod Pump

April 14, 2016

article originally posted with EmpoweringPumps.com
Author: Steve Smith, President & Founder, TechValve Industries LLC

What inspires engineers to create new pumps? The inspiration to design new pumps, and even valves and other industrial equipment, stems from seeing a need. A problem to solve. An issue to address. Engineers around the globe spend countless hours engineering solutions to solve the world’s problems.

As a member of the engineering community, I have been inspired to design several pieces of industrial equipment over the years. Eight of my twelve patents are for different pumps and valves, and most of them were created as a result of needing a better solution than what had been available at the time.

For instance, one company I previously worked with originally hand-mixed a two-part silicone gel liquid for a potting process. As that company grew and demand for that company’s product increased, the hand-mixing of that silicone took too much time and people on the assembly line could not keep up with the increase in production. That led me to design and build my first dispense machine.

Initially, I used a programmable logic controller (PLC) along with two gear pumps, but quickly realized that gear pumps were not ideal for the very thick and viscous materials that were being pumped. The next set-up used progressive cavity pumps; and while they were good for low pressure applications, they ended up being incompatible with many of the materials our customers needed to process in other applications. The chemicals attacked the elastomeric portion of the pump stator and caused a lot of problems.

Then I began working with rod pumps, which are very powerful and highly accurate. The only problem with the rod pump was that it did not provide continuous flow. Once all the fluid in the rod pump had been dispensed, the pump had to reverse and refill itself before it could dispense fluid again. This is an issue for any application that cannot have a pause in the pump cycle. Take for example a painting application. A pause in the pump cycle would mean spray is lost and the result would be uneven coverage. Imagine a robot painting the side of a car in an automotive assembly line, and all of a sudden, it runs out of paint. The robot doesn’t know that; it just keeps on going, and now there is an area that hasn’t been covered. Seeing the potential to improve upon rod pump capabilities, I set out to design the world’s first double-acting rod pump.

Dual Action Rod Pump
Dual Action Rod Pump

In 2000, I used AutoCAD to design the dual action rod pump (DARP). From the design phase to having a prototype on the bench took about 30 days. The first prototype of this pump was built in my garage, and initial performance tests proved the DARP worked perfectly. The DARP really gained traction after it was successful in helping an aerospace company with their proprietary metal coating, which had been grinding up every pump they had tried using. The DARP worked great for their application because it could pump anything. There is no metal to metal contact between the pump rod and the fluid cylinder; therefore there is nothing to wear out – no pistons or piston seals, etc. The DARP is essentially a universal pump –

  • The DARP is 100% chemically compatible. Over the past 15 years, thousands of our dual acting rod pumps have been used in factory automation applications, aerospace, military, and other industrial processes. To date, there has not been a chemical used that has caused the DARP to degrade or fail. Furthermore, the DARP can “run dry” for extended periods of time without damage or failure.
  • The DARP has 100% volumetric efficiency with any viscosity and any pressure. To explain this concept of volumetric efficiency, let’s say you have a gear pump set up next to a piston pump set up next to a dual action rod pump. They’re all the same capacity -they can put out 1 ounce per minute at zero back pressure. Now you turn on the gear pump and give it some back pressure. You see the output drops because it has slip factor (the material can actually slip inside the pump). Instead of dispensing 1 ounce, slip factor might cause that gear pump to only dispense three quarters of an ounce, making that pump only 75% efficient. Air-operated pumps exhibit similar performance issues; i.e. the higher the back pressure, the less output. With the rod pump, there is no change in output. The DARP can dispense one ounce per minute whether the back pressure is 0, 100, 1000, 2000, 3000 or higher. There is no slip factor at any pressure. Let’s say we have 2 dual action rod pumps, and we put water in one and peanut butter in the other one (both with the same capacity). If we ran them both 10 revolutions, we would get the exact same output of water and peanut butter – volumetrically-speaking. The pressure for the DARP pumping peanut butter might be 3000 PSI while the pressure for the DARP pumping water is only 1 or 2 PSI, but the pumps will output 2 ounces of water and 2 ounces of peanut butter. This is the beauty of the DARP – the pressure does not matter because there is no slip factor. The only thing that could stop the DARP are the rotations of the motor that’s driving it. Using a weak motor will stall the pump; this is why we use servo motors to power this pump, which has been tested to handle pressures up to 20,000 PSI.
  • It’s a servo-driven “smart” pump. Servo motors provide high accuracy metering and our proprietary remote controllers are customized for the end user and the specific application the dual action rod pump will be operating in. The DARP is truly a smart pump because the controller knows what the pump is capable of. It won’t allow the operator to perform an action that the pump is not capable to perform. The controller knows how to control the pump based on whatever the operator is asking the pump to do.

This smart pump presents a great opportunity for the bio-tech industry. We’ve spent the last 3 years working on a whole new generation of dual action rod pumps that specialize in really low flow. This new DARP is capable of dispensing extremely small quantities of fluid over very long periods of time without any pulsations. The biotech industry (this includes companies developing new medicines and labs conducting cancer research) has spent years scrapping “bad samples” because the peristaltic pumps they typically rely on to dispense fluid create pulses during operation. Now there is an alternative – an engineered solution to help improve micro-fluidic processes within the biotech industry.

The DARP provides a solution for preventing a “bump” in the dispense routine. A “bump” is generally an upset in the flow of fluid, which is typically caused by the pump changing direction or experiencing a fluctuation in pressure. Reciprocating pumps can’t handle a change of direction in a dispense routine. Gear pumps pulse with every gear shift and exhibit high frequency fluctuations in output, as do progressive cavity pumps. The upset in the flow that can happen in the middle of a sample is a major issue for the biotech industry, and the DARP addresses all those issues.

The DARP provides continuous flow and never changes direction in the middle of a sample. This “smart” pump knows when it has reached the point where it cannot create one full sample. At this point, the control screen tells the operator that it cannot produce more samples until the pump changes direction. Once prompted by our proprietary software, the operator needs only to press a button to allow the pump to change direction and produce another set of samples. The controller will only allow the pump to go as far as it can go to finish the last routine, but it won’t start another routine it can’t finish without changing direction. For example, if the pump is reaching the end of its stroke, and it has been asked to provide a 10cc output, but it is only capable of dispensing 8cc’s – it won’t dispense 8cc’s. The DARP will stop and an alert notice will appear on the screen telling the operator that they have reached the limit of output for that stroke. The operator is then allowed to initiate the change of direction to ensure the same amount of dispense routines goes in the other direction. This way there will never be a change of direction in the middle of a sample.

We see many opportunities for the Dual Action Rod Pump to have a positive impact in a wide range of applications. Visit www.techvalveind.com to watch a video of the DARP pump in action!

About the Author

Currently the Co-Program Director and Principal Investigator for California Cardiac Solutions, LLC., Steve Smith has over 12 years’ experience as a Director of Mechanical Engineering; having worked with factory automation, robotics, CNC/PLC computer controls and servo drive systems. Smith holds numerous patents and has 22 years of experience in the design, development, and manufacturing of high precision fluid metering systems and fluid control circuits.

For more information, visit www.techvalveind.com. You can contact Steve Smith at ssmith@techvalveind.com, or his associate, Glenn Dietz gdietz@kzagroup.com.

Filed Under: What's New and Noteworthy

A Life-Changing Pump: The Freedom Heart

April 6, 2016

article originally posted with EmpoweringPumps.com
Author: Steve Smith, President & Founder, TechValve Industries, LLC

The heart is the most precious pump. There are currently many Americans living with heart problems that deeply understand this fact. In 2015, roughly 750,000 Americans died from congestive heart failure. With about 30,000 donor hearts currently available each year, there is clearly an urgent need for artificial hearts.

Freedom Heart article image

Artificial hearts currently available to the public are really only “bridge-to-transplant” Pump in Palm of Handoptions. They are temporary installations that are implanted to help patients in the most dire of situations. Once implanted, the artificial heart only lasts between 12 to 18 months before it breaks down and needs to be replaced.

As an engineer who has been designing pumps, valves, and fluid handling systems for many years, I decided to revisit a pump design I had started working on many years earlier. With technology being what it is today, I set out to design an artificial heart that would achieve three major goals:

  1. Make an artificial heart that can be more of a permanent solution – not just a “bridge-to-transplant” option. If we could provide patients on the heart-transplant list with an artificial heart that could operate for several years, maybe even decades, the need for donor hearts would decrease and additionally survival rates of patients might be improved.
  2. Design the artificial heart to be fully implantable. The most commonly implanted artificial hearts, which are essentially pneumatically-operated diaphragm pumps, require exterior devices. The pneumatically-operated artificial heart requires two air lines, an inlet and an outlet, to be inserted into the patient’s chest. The patient is always at risk of infection due to the tubes penetrating the patient’s skin. Therefore such areas have to be cleaned twice a day to avoid risk of infection. Moreover, patients have to carry an air compressor, which is battery-operated and can weigh up to 16 lbs. Designing an artificial heart that is fully implantable would eliminate the cumbersome task of carrying this excess weight. This would vastly improve the patient’s quality of life.
  3. Ensure the artificial heart is redundant. A major problem with the design of available artificial hearts is that there is currently no “back-up” mechanism. Patients who rely on pneumatically-operated artificial hearts can carry around a back-up compressor with batteries, but if something within that artificial heart fails, the person will be gone within minutes. Therefore, it would be critical to design a fully redundant artificial heart.

Using Turbine Technology to Create a Pulse-less Artificial Heart

In the past, many doctors tried designing artificial hearts to mimic the natural heart. These designs relied on some type of diaphragm or flexible membrane to move back and forth. The problem is that anything that flexes breaks down over time. In order to create an artificial heart that could operate reliably over a long period of time, we concluded that having a heartbeat just wasn’t necessary.

Freedom Heart pump image

Using a quad-turbine based design, our Freedom Heart has two sides (similar to the left and right chambers of the heart) in which each side has two independent turbines. The turbines are driven by frameless servo motors, which supports redundancy. If one of the turbines fails, there are three more running turbines to ensure that the artificial heart does not fail altogether.

By running multiple turbines, we addressed an important issue concerning speed. An artificial heart driven by a single-turbine would have to spin at an extremely fast rate to provide adequate blood flow – at speeds around 25,000 RPM. Unfortunately, high speeds result in hemolysis of the blood being pumped (damage to and/or destruction of the red blood cells). By running multiple turbines and employing the principles of differential pressure, we were able to achieve the required pressure and flow at much slower speeds.

Freedom Heart pump turbines

The Freedom Heart utilizes two micro controllers which are mounted on one board; so if one microprocessor fails, the other one takes over to keep the heart running. This revolutionary artificial heart is designed to have two inductive battery packs that can be fully implanted. This method of battery charging, known as induction, will enable patients to charge the Freedom Heart battery right through their skin (similar to an electric toothbrush being charged through the plastic). The Freedom Heart will also have Bluetooth as well as telemetry on board so if there is an anomaly of any kind, the patient and his or her physician along with everybody on the patient’s emergency contact list will receive a phone call. When the patient arrives at the doctor’s office, the Freedom Heart can be examined and adjusted, and if necessary adjusted wirelessly once the IP address is accessed.

Getting the Freedom Heart to Market

We’re currently working with attorneys to go through the FDA approval process. We hope to move forward with blood trials, followed by clinical trials, and hopefully, eventually human trials to make the Freedom Heart available to the public. While we wish this process would go more quickly, we recognize that it will be a few years before this life-changing pump will be available to help people who suffer with heart problems.

We anticipate that our patented design of the Freedom Heart – (being a servo-driven, quad-turbine based system) – will have a minimum of a 10 to 15-year life cycle. As the Freedom Heart will be encapsulated in bio-compatible materials, there will be no need for patients to take anti-rejection drugs. Patients will therefore save money on medications as well as avoid unwanted side effects from anti-rejection drugs. This will further improve a patient’s quality of life.

The Freedom Heart has been created to act as a permanent replacement for the natural heart. We’re hoping that instead of waiting for a donor heart, and risking kidney failure, liver failure, and other organ damage that can happen with a failing heart, a patient will have the option to replace his or her failing heart with a permanent solution. And maybe one day, choosing the Freedom Heart will be as commonplace as a hip replacement.

About the Author

Currently the Co-Program Director and Principal Investigator for California Cardiac Solutions, LLC., Steve Smith has over 12 years’ experience as a Director of Mechanical Engineering; having worked with factory automation, robotics, CNC/PLC computer controls and servo drive systems. Smith holds numerous patents and has 22 years of experience in the design, development, and manufacturing of high precision fluid metering systems and fluid control circuits.

For more information, visit www.techvalveind.com. You can contact Steve Smith at ssmith@techvalveind.com, or his associate, Glenn Dietz gdietz@kzagroup.com.

Filed Under: What's New and Noteworthy

SONO Ultrasound Wipes Compatibility Testing

February 3, 2016

Kaizen Automation Group, Inc.designed and provided the software development, Trio Motion Technology MC403 three axis controller, 7″ Trio Uniplay HMI, motors and drives and fully integrated the system. We can develop OEM multi-axis machinery for you. Contact Glenn Dietz for more information or a quote on your OEM project.

Filed Under: What's New and Noteworthy

Capabilities

  • System Integration Services
  • Custom Software Solutions
  • Value Added Products and Services
  • Motion Control
  • Machine Automation and Retrofit
  • OEM Custom Machine Fabrication
  • Partner Products

Copyright © 2023 KaiZen Automation Group Inc.  //  926 S. Andreasen Drive, Suite 106, Escondido, CA 92029  //  1-888-837-8180
Privacy Policy/Terms of Service | Accessibility Statement